LSR Liquid Silicone Rubber Injection Molding Machine
MINHUI LSR injection molding equipment is intended for liquid silicone rubber projects. Select the press, material metering package, injection unit and mold as a complete system. Application examples alone do not establish suitability for a particular material grade or finished product.
LSR Injection Molding Machine Overview
Applications
- LSR liquid silicone rubber injection molding machine is use for the liquid silicone injection molding in products, like: lighting, communications, medical, toys, baby products, daily necessities and other industries, and is widely used.
- Typical products: Mobile phone waterproof fittings, watchband, electronic bracelet, baby supplies such as pacifiers, diving masks, silicone phone cases, coasters, and silicone adult products.
Characteristics
- Electrical insulation requirements must be checked against the selected material grade and finished-component tests.
- Service-temperature limits and changes in mechanical or electrical properties depend on the selected LSR grade, exposure conditions and test method. Use the material supplier’s data and validate the finished part.
- Review aging, weathering and other service requirements against the selected material grade and finished-part test conditions.
- Confirm the selected material grade, proposed sterilization method and finished-part validation for medical or baby-product projects.
- The ejector pin can be used with different sliding plates and the stroke can be adjusted freely. The remolding force, ejector in / out speed and remolding times can also be pre-set as required.
Features
- Multi-stage precision mold heating controller
- LSR special hydraulic water-cooled closed nozzle
- LSR special screw & barrel part
- Thermal cold plate.
- Insulating fiber board.
- Rotary or double sliding table design(1pc top with 2 pcs bottom mold), higher efficiency.
- Confirm the metering arrangement and any optional vacuum equipment. Bubble control also depends on material handling, mold venting and the validated process.
- Professional computer, high precision, easy to operate.
- Confirm the quoted servo-drive configuration. Compare measured energy consumption using the same part, mold, material and complete operating cycle; no universal saving percentage is specified here.
- The pictured configuration uses vertical clamping and vertical injection, with a horizontal work table for loading inserts.
- A double sliding table provides a separate handling position. Review the supplied guarding, interlocks and operating instructions for the complete cell.
MINHUI MH-LSR Injection Molding Machine Specifications
Compare eight MINHUI liquid silicone rubber (LSR) injection molding machine models, from 60 to 160 tf of clamping force. Use the platen dimensions and opening stroke to shortlist models, then confirm mold fit with your mold drawing.
| Model | Clamping force (tf) | Opening stroke (mm) | Platen size, L × W (mm) |
|---|---|---|---|
| MH-60T-1S-LSR | 60 | 200 | 436 × 420 |
| MH-60T-2S-LSR | 60 | 200 | 860 × 450 |
| MH-85T-1S-LSR | 85 | 250 | 490 × 540 |
| MH-85T-2S-LSR | 85 | 250 | 1,150 × 500 |
| MH-120T-1S-LSR | 120 | 280 | 560 × 570 |
| MH-120T-2S-LSR | 120 | 280 | 1,260 × 570 |
| MH-160T-1S-LSR | 160 | 300 | 720 × 730 |
| MH-160T-2S-LSR | 160 | 300 | 1,440 × 730 |
For a model recommendation, include your LSR grade, mold dimensions and cavity count in your quote request. Confirm the injection unit and A/B metering package for the selected model.
LSR Metering System: Published Reference Values
This published sheet describes an LSR metering arrangement, not a uniquely identified press model. Confirm the selected press, dosing package, material grade and current specification together.
| Parameter | Published value |
|---|---|
| Material and container sizes | The original metering-system specification lists 20 kg and 200 kg containers for two-component (A/B) liquid silicone rubber. Confirm the compatible container size for the selected A/B metering system. |
| A:B ratio by volume | 1:1; stated tolerance <2% |
| Adjustable flow rate | 0.1–2 L/min |
| Material viscosity range | 400–1200 Pa·s; test temperature not stated |
| Electrical rating shown | 380 V, 4 kW. The original sheet lists 210–550 V configurations depending on destination. Confirm the quoted supply voltage. |
| Compressed-air pressure | Above 0.6 (the source prints the unit as “Mp”). Confirm the pressure unit and air-supply requirement for the quoted configuration. |
The sheet does not fully define test conditions, press clamping force or the installed electrical configuration. Confirm these for the actual project rather than treating the metering values as universal ratings for all LSR machines.
LSR Injection Sample Display
Selecting an LSR Injection Molding System
Metering and Mixing
Confirm the material components, ratio and ratio basis, viscosity conditions, delivery arrangement and any color or additive equipment. The required tolerance and verification method must be defined for the selected system; a ratio statement alone is not proof of metering performance.
Injection and Thermal Control
LSR processing separates material delivery and injection requirements from the mold’s curing conditions. Confirm the injection unit, nozzle arrangement, temperature control and thermal interfaces for the selected material and tooling. Do not copy barrel or mold settings from an unrelated resin or model.
Mold and Part Handling
Review mold dimensions and weight, mounting, heating, vents, demolding and any inserts or services. Compare fixed, sliding or rotary handling using the actual loading and removal sequence, tool compatibility and complete cell clearances.
What Belongs in a Proposal?
- Identified press, metering package, injection configuration and current model documents.
- Material and tooling requirements, shot volume, cavities and acceptance criteria.
- Auxiliaries, factory electrical supply, cooling and other services.
- Protective devices, interfaces, automation, records and integration responsibilities.
- Representative trial conditions and the agreed evidence for output, dimensions and other required results.
Related Illustrations
Illustrations are not a selected-model specification, service instruction or verified performance result.
Is the Metering Sheet a Complete Machine Specification?
No. The published reference table above describes an LSR metering arrangement, not a uniquely identified press model. Its flow, ratio and electrical values must not be used as the clamping-force, shot-capacity or total installed-power rating of the complete cell.
What Should Be Confirmed Before Model Selection?
- Material supplier, exact LSR grade, component ratio and processing instructions.
- Part and runner volume, cavity count, critical dimensions and acceptance criteria.
- Metering and mixing package, injection-unit capacity and temperature-control requirements.
- Mold dimensions, heating, venting, demolding and any insert-retention requirements.
- Loading sequence, station layout, automation, factory services and destination requirements.
Can Any Silicone Grade Be Used for Medical or Baby Products?
No. Material grade, finished-part design, process validation and applicable destination requirements need separate review. A machine application label does not certify the material or the finished product.
The exact grade, finished design, manufacturing, intended use and any downstream treatment require separate evaluation. The machine-family name is not finished-product approval.
Does a Rotary or Sliding Table Define the LSR Process?
No. Those terms describe mold handling. Compare the rotary and sliding table arrangements after confirming the material system. Use the vertical machine selection checklist and the metering reference table above for project review.